ASTM D1196 PDF

All the Controls products ASTM D standard. Enter now!. 11 Jan Buy ASTM D/DM() Standard Test Method for Nonrepetitive Static Plate Load Tests of Soils and Flexible Pavement. Designation: D/DM – Standard Test Method for. Nonrepetitive Static Plate Load Tests of Soils and Flexible Pavement Components, for Use in.

Author: Dorisar Visho
Country: Guinea-Bissau
Language: English (Spanish)
Genre: Education
Published (Last): 27 December 2006
Pages: 118
PDF File Size: 2.61 Mb
ePub File Size: 10.87 Mb
ISBN: 915-4-17527-858-3
Downloads: 81126
Price: Free* [*Free Regsitration Required]
Uploader: Tagrel

From this graph, the relation of load and total deflection for that load, and the relation of rebound and residual deflection for the maximum load used, may be obtained. Be the first to comment!

Plate Load Test Standard ASTM D DM – Free Download PDF

If you need to be able to add standards to the monitoring service, you must register as a user with your own username and password. Please copy and paste this embed script to where you want to embed Embed Script.

Please help us to share our service with your friends. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. At this point, maintain the load until an increased deflection of not more than 0.

The values stated in each system may not be exact equivalents; therefore, each d119 shall be used independently of the other. The magnitude of each load increment shall be small enough to permit the recording of a sufficient number of load-deflection points to produce an accurate load-deflection curve not less than six.

For evaluation purposes alone, a single plate may be used, provided that its area is equal to the tire-contact area corresponding to what may be considered as the most critical combination of conditions of wheel load and tire pressure.

TOP Related Articles  OPERACION PRIMICIA CEFERINO REATO PDF

When the dial needles come to rest following release of this load, reseat the plate by applying one half of the recorded load producing the 0. Current edition approved Jan. It involves the determination of oxidizability, also known as oxygen O2 demand, by potassium permanganate ISO method For the purpose of providing data indicative of bearing index for example, the determination of relative subgrade support throughout a period of a yeara single plate of any selected size may be used.

Record of Tests 6. The diameters of adjacent plates in the pyramid arrangement shall not differ by more than mm [6 in. Please fill this form, we will try to respond as soon as possible. Calculation and Plotting of Load-Deflection Relationships 7.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Webprint Printed and bound.

After each increment of load has been applied, maintain the load until a rate of deflection of not more than 0. Each individual set of readings shall be averaged, and this value is recorded as the average settlement reading.

What is permanganate index? Start Webshop Product catalog Product presentation.

ASTM D, Test equipment Controls

Field, in-place xstm static load tests are used for the evaluation and design of pavement structures. Read more about satm. Soils and flexible pavement components at the same location may exhibit significantly different load deflection relationships. Subscription – always available and updated A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition.

TOP Related Articles  APRENDER INGLES EN 7 DIAS RAMON CAMPAYO EPUB DOWNLOAD

Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work.

ASTM D1196/D1196M – 12(2016)

Also plot the recovery after full release of load. The subcommittee is seeking pertinent data from users of this test method that may be satm to develop meaningful statements of precision and bias.

We need your help! Replaces D — The moment new editions of the standards you monitor are released, changes are made, or appendixes are published, you will be alerted by email. Originally approved in Monitoring Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of asttm standards required in your work.

Record the deflection at the zero-setting load. The entire deflection measuring system shall be adequately shaded from direct rays of the sun. When the dial needles have then again come to rest, set each dial accurately at its zero mark. New rules for flare stack combustion from the US Environmental Protection Agency EPA set to take effect in early include additional monitoring and analysis requirements that make it necessary for refinery operators to quickly and accurately determine the heat values of flare stack gases.

A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. To achieve this, the recommended